Description
6600-166, Sundance® Spas and Sweetwater Spas Temperature Sensor with Curled Finger Connectors.
(Use with 6540-228 Oring (sold separately, see below in related products.)
Temperature Sensor fits these Sundance® Spas Models:
- 2012+ 680 Peyton® (04/2012+)
- 2011+ Select Series: Constance and Victoria
- 2008+ Camden, Chelsee®, Certa, Denali®, Tacoma®, Hawthorne, Hartford, Hamilton, Dover
- 2008-2012 Burlington
- 2007+ Hamilton, Chelsee®, Certa and Camden, Montclair and Dover
- 2007 Metro, Solo, Burlington, Denali®, Tacoma®
- 2006 Caprio, Palermo, Bahia and Cayman Metro, Solo, Burlington, Denali®, Tacoma®
- 2005 Sweetwater, Del Sol and 850E Series: Lagunas, Cayman, Bahia, Palermo, Solo, Metro, Caprio
- 1998-2004 Sweetwater Series and Portofino Series: Aspen®, Austin, Bahia, Caprio, Caprio ST Cayman, Cheyenne, Hartford, Lagunas, Madison, Metro, Olympia, Palermo, Solo, Tango, Vail
- All Lx-10 and LX-15 Systems used by Sundance® Spas : 1998: Vail, Olympia, Madison, Hartford, Cheyenne, Austin, Aspen®
- All 1998-2007 701, 724 Systems (with curled Finger Connectors)
- Winchester, Kensington Spas (with curled finger connections)
- No longer used on 780 systems after 04/2017+
Replaces 6600-070, 6600-071 6600-104.
Used on All: Austin, Aspen®, Bali, Bahia, Burlington, Caprio, Cayman, Camden, Certa, Chelsee®, Cheyenne, Denali®, Dover, Hamilton, Hartford, Hawthorne, Lagunas, Madison, Metro, Palermo, Solo, Tacoma®, Vail
Used on these Circuit Boards: 6600-720, 6600-726, 6600-722, 6600-724, 6600-286, 6600-287, 6600-288, 6600-289, 6600-082, 6600-084, 6600-086, 6600-087, 6600-088, 6600-089
Temperature Sensor fits these Jacuzzi® Spas Models:
- 2007+ J-270, J-280, J-355, J-365 and J-375 Models
- 2005+ J-210, J-220 and J-230, J-200 LED Models
- 2005-2007 J-325 Models
- 2004+ J-335, J-345 Models
- 2003-2005 Del Sol Models
- 2002-2003 J-320, J-330, J-340 Models
- 2002+ J-300
The Temp Sensors are located in the filter compartment on the side. They are unscrewed from the inside of the tub and the wire is fed through the tub into the equipment compartment. Follow the wire to the PC Board. To feed the new sensor, we usually drain the tub below the hole and pull the old sensor out a couple of feet into the tub, cutting the old sensor head off, we tie on the new sensor (connector end) to the old wire and pull the wire through into the equipment compartment.
The connectors on the Temp Sensor are attached to a pc board connector that is located on the PC Board (usually at the top). There are other wires connected to this plug: Jumper interlock wire,Flow Switch, High Limit and Temp sensor. Remove the pin connector from the board .
Please note: The color code on the wires have no significance, you can hook the wires up either way.